Compact control unit for ECOTAP® VPD® on-load tap-changer

Achieve precise voltage regulation with ECOTAP® VPD® Control – the compact control unit designed specifically for the ECOTAP® VPD® on-load tap-changer (OLTC). Intuitive to operate and adjust – it continuously monitors low-voltage levels and ensures optimal tap-changer performance, delivering stability and efficiency for today’s dynamic power grids.

ECOTAP® VPD® Control is the dedicated controller for the ECOTAP® VPD® OLTC, engineered to provide reliable voltage management in evolving grid environments. By measuring voltage on the LV side and actuating the tap changer motor-drive unit, it guarantees consistent voltage.

Its intuitive interface simplifies on-site handling, offering clear displays and easy navigation for technicians. For advanced connectivity, the unit supports MODBUS RTU communication, enabling seamless integration into existing grid architectures and SCADA systems.

Compact yet powerful, ECOTAP® VPD® Control combines robust design with smart functionality – making it the ideal choice for utilities and industrial applications seeking cost-effective voltage regulation without complexity.

Dedicated Control for ECOTAP® VPD OLTC
  • Specifically designed for all ECOTAP® VPD on-load tap-changer variants
  • Ensures precise LV-side voltage measurement and motor actuation
  • Intelligent single-phase voltage control algorithm for automatic operation
Easy Commissioning
  • Plug-and-play connection via coded plug-in systems to prevent errors
  • Intuitive display with clear status indicators
  • Fast reorder via serial-number-based preset
Flexible Integration
  • MODBUS RTU interface for seamless SCADA and grid connectivity
  • Parameterization possible without a laptop through direct setup of the device on-site
  • Dynamic setpoint possible to adopt on different grid conditions (Control DS option)
Compact & Versatile Design
  • Space-saving dimensions: only 10 cm wide and 35 cm high
  • Multiple installation options: on transformer, in control cabinet, or on busbar
  • Robust construction for reliable long-term performance
Suitable for all versions of the ECOTAP® VPD® on-load tap-changer®

The ECOTAP® VPD® Control product family comprises three variants, each tailored to different application requirements. All variants feature automatic voltage regulation, intuitive operation, and compact design. However, the Control DS offers additional features such as an input for single-phase current measurement and dynamic setpoint adjustment depending on active power flow. The e.on variant is specifically preconfigured for distribution network operators of the e.on group with corresponding Modbus parameter settings.

Variants Control Standard Control e.on Control DS
Single-phase automatic voltage regulation
Parameterization possible without laptop
Extensive status indicators on display
Plug-and-play connection via plug
Compatibility with all ECOTAP® VPD® variants
Input for single-phase current measurement
Dynamic setpoint adjustment (Dynamic Setpoint))
Measured value memory (approx. 1 year)
Special Modbus parameters for e.on group
Legend

✓ = available | ✗ = not available

What you get:
  • 1 box with ECOTAP® VPD® Control DS unit
  • 1 nameplate sticker
Dokumente
Name Kategorie Datum Größe Download
ECOTAP® VPD® Control Manual Operating instructions 11.07.2025 5 MB
FAQ - Frequently Asked Questions
What else do I need in addition to this control unit?

This control unit provides the switching pulse for the motor drive, which switches the ECOTAP® VPD® on-load tap changer. These three elements turn a standard distribution transformer into a controllable transformer that can maintain the voltage within a defined voltage range. The control units can be used for all ECOTAP® VPD® on-load tap changers, including the single-phase versions.

What is the difference between the ‘Standard’ and ‘e.on’ options?

Both versions have the same functionalities. However, the ‘e.on’ version has different MODBUS settings for the applications of this distribution network operator.

What can I do with the MODBUS RTU interface?

This interface allows the control unit to be connected to an additional “Control PRO” unit or to a gateway including a MODBUS converter for remote communication. This enables data to be read out or switching commands to be issued externally. For commissioning, the control unit can also be connected to a laptop, from which data can be uploaded.

Can I replace old control units with new ones?

Yes, all control units supplied with the ECOTAP® VPD® load tap changer to date can be easily replaced with a new control unit. The dimensions are identical, as are the dimensions of all three variants.

Problem with the installation? No problem at all!

Discover our how-to videos for many products.

Welcome to our how-to videos section, your ultimate guide to easy installation, commissioning and maintenance. Our videos provide you with clear and understandable instructions specifically designed to make it easier for you to use our products.

These videos complement our operating instructions and provide additional visual support for a seamless implementation of your projects. Take a look at our videos and make your life easier.

Lorem Ipsum dolor sit amet

Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Lorem Ipsum dolor sit amet

Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Lorem Ipsum dolor sit amet

Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Dissolved Gas Analysis (DGA)

Download the DGA Application Guide and protect your transformers from unexpected failures

Our free Application Guide provides information on how Dissolved Gas Analysis (DGA) can help detect transformer failures early.

Learn what problems are caused by gases in the transformer oil and how continuous monitoring of hydrogen, carbon monoxide and moisture using an online DGA sensor can help prevent costly transformer downtime.

With your newfound knowledge, you can improve your equipment monitoring and minimize the risk of downtime and costly repairs.

Request DGA Application Guide for Free
Privacy
Fields marked with asterisks (*) are required.
Request DGA Application Guide for Free

Fields marked with asterisks (*) are required.

Loading...
Upload in progress, please be patient ...